EcoGreen66 - Initial GMax Test
|
TESTINGSERVICES, INC. 817SHOWALTER AVE. • P.O. BOX 2041 DALTON,GEORGIA 30722-204 1 PHONE: (706)226-1400 • FAX: (706) 226-6118 |
TEST REPORT
|
CLIENT: |
FieldShield Inc. |
REPORT NUMBER: |
41020 |
|
11Skylar Drive |
LAB TEST NUMBER: |
1920-2966 | |
|
Southboro, MA 01772 |
DATE: |
April16, 200 |
Product Description: 66 oz/yd2 Synthetic Turf with1.5” Pile Height
Turf ID: EcoGreen 66
Infill System: 1.1 lbs/ft2 Organite by FieldShield,Inc.
Drainage System: EcoFlo
Liner System: 20 mil Geo membrane
Sub Base: Compacted Soil
Test Scope: Data obtained from this test method are indicative of cushioning properties of the playing
surface system and materials under the specific conditions selected. The playing system is impacted at a specified velocity with a missile of given mass and geometry to determine the maximum value of G encountered during impact.
Test Method: ASTMF355-01: Standard Test Methods for Shock-Absorbing Properties of Playing
Surface Systems and Materials (Procedure A)
Test Equipment:
Description: Clearview Bumper mfg byTSi (US Patent # 6,925,898 B2)
Tube: Clear Acrylic
Missile Weight: 9.1 kg (20 lb)
Missile Circumference: 29 cm2 (20 in2)
Data Collection: Oceana Sensor (Bluetooth)with ICBM Monitor Software
Test Procedure: The infilled turf waspositioned over the sub base with the clearview bumper (gmax test
equipment) placed levelover the entire playing surface system. The missile was released, so as to impact thecenter of the assembly at a velocity of 3.43 m/s at a drop height of 24”. Threedrops were made at 3minute intervals. The first drop was for assemblyconditioning and was not included in the average.
Test Results: Test Date: April 1, 2008
Test Environment: 63°F 32% RH
|
G-Max Read Drop #2 |
G-Max Reading Drop #3 |
Average G-Max Reading |
|
126 |
134 |
130 |
Approved By: Erle Miles Jr VP TestingServices Inc
OUR LETTERS AND REPORTS APPLY ONLY TO THE SAMPLETESTED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLYIDENTICAL OR SIMILAR PRODUCTS,THESE LETTERS AND REPORTS ARE FOR THE USE ONLY OF THE CLIENT TO WHOM THEY AREADDRESSED AND THEIR COMMUNICATION TO ANYOTHERS OR THE USE OF THE NAME TESTING SERVICES, Inc. MUST RECEIVE OUR PRIORWRITTEN APPROVAL. THE REPORTS AND LETTERS, AND OUR NAME, OUR SEALS, OR OUR INSIGNIA ARE NOT UNDER ANYCIRCUMSTANCES TO BE USED IN ADVERTISING TO THE GENERAL PUBLIC.
VISIT OUR WEBSITE AT www.tsiofdalton.com